<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Service &amp; Part Replacement - OEM Parts for Hatco Equipment | Hatco Trade Direct Parts</title>
	<atom:link href="https://www.hatcodirect.com/category/videos/service-and-part-replacement/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.hatcodirect.com/category/videos/service-and-part-replacement/</link>
	<description>OEM Parts for Hatco Equipment &#124; Hatco Trade Direct Parts</description>
	<lastBuildDate>Tue, 26 Sep 2023 19:33:15 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://www.hatcodirect.com/wp-content/uploads/2025/02/hatco-direct-oem-parts-icon-32x32.jpg</url>
	<title>Service &amp; Part Replacement - OEM Parts for Hatco Equipment | Hatco Trade Direct Parts</title>
	<link>https://www.hatcodirect.com/category/videos/service-and-part-replacement/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>How to Replace the Controller on HHS Units</title>
		<link>https://www.hatcodirect.com/how-to-replace-the-controller-on-hhs-units/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Tue, 26 Sep 2023 18:03:48 +0000</pubDate>
				<category><![CDATA[HHS Series]]></category>
		<category><![CDATA[Service & Part Replacement]]></category>
		<guid isPermaLink="false">https://www.hatcodirect.com/?p=22077</guid>

					<description><![CDATA[<p>A step-by-step tutorial for Replacing the Controller within HHS Units In the food service industry, malfunctioning equipment can significantly disrupt business flow, resulting in decreased profits and unhappy patrons. At FWEParts, we&#8217;re dedicated to offering comprehensive tutorials that guide you through a quick repair process. In this piece, we&#8217;re introducing a detailed video tutorial centered [&#8230;]</p>
<p>The post <a href="https://www.hatcodirect.com/how-to-replace-the-controller-on-hhs-units/">How to Replace the Controller on HHS Units</a> appeared first on <a href="https://www.hatcodirect.com">OEM Parts for Hatco Equipment | Hatco Trade Direct Parts</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph"><strong>A step-by-step tutorial for Replacing the Controller within HHS Units</strong></p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<p class="wp-block-paragraph">In the food service industry, malfunctioning equipment can significantly disrupt business flow, resulting in decreased profits and unhappy patrons. At FWEParts, we&#8217;re dedicated to offering comprehensive tutorials that guide you through a quick repair process. In this piece, we&#8217;re introducing a detailed video tutorial centered on replacing the Controller in FWE HHS models. If you are still experiencing issues with this, or any other part, please do not hesitate to reach out via phone at <a href="tel:16158053270">1-615-805-3270</a> or email at <a href="mailto:service@hatcodirect.com">service@hatcodirect.com</a> if you have any questions or concerns.</p>



<figure class="wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio"><div class="wp-block-embed__wrapper">
<iframe title="FWEParts | HHS Series | How to Replace the Controller" width="1140" height="641" src="https://www.youtube.com/embed/NMDVxlnf_YI?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" allowfullscreen></iframe>
</div></figure>



<h3 class="wp-block-heading">Parts Covered in this Tutorial</h3>



<ul class="wp-block-list">
<li><a href="https://www.hatcodirect.com/part/z-600-2403/">Z-600-2403</a></li>
</ul>



<h3 class="wp-block-heading">Tools Needed</h3>



<ul class="wp-block-list">
<li>1/4&#8243; Nut Driver</li>



<li>Needle Nose Pliers</li>
</ul>



<h3 class="wp-block-heading">Steps</h3>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=NMDVxlnf_YI&amp;t=0s">0:00</a> | Introduction </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=NMDVxlnf_YI&amp;t=20s">0:20</a> | Step 1: Remove the two screws securing the control housing and pull out the housing from the unit. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=NMDVxlnf_YI&amp;t=29s">0:29</a> | Step 2: Locate controller and remove the connections, taking note of their locations. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=NMDVxlnf_YI&amp;t=40s">0:40</a> | Step 3: Remove clips holding in the controller and pull the controller out of the mounting hole. Discard the old controller. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=NMDVxlnf_YI&amp;t=50s">0:50</a> | Step 4: Insert the new controller into the existing mounting hole and secure using the clips removed from Step 3. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=NMDVxlnf_YI&amp;t=61s">1:01</a> | Step 5: Reinstall the controller connections removed in Step 2. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=NMDVxlnf_YI&amp;t=79s">1:19</a> | Step 6: Reinstall the control housing and secure it with the screws removed in Step 1. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=NMDVxlnf_YI&amp;t=91s">1:31</a> | Step 7: Restore power to the unit and test for operationality. Return the unit to service.</p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<p class="wp-block-paragraph">In the food service industry, equipment breakdowns can be disruptive and costly. That&#8217;s why FWEParts is committed to providing step-by-step tutorials that make equipment repairs a breeze. If you&#8217;re facing issues replacing the Controller within an HHS unit, our service video offers a comprehensive guide to easily troubleshoot it using common tools. We&#8217;re here to support you every step of the way, so don&#8217;t hesitate to reach out to us at <a href="tel:1-615-805-3270">1-615-805-3270</a> or <a href="mailto:service@hatcodirect.com">service@hatcodirect.com</a> if you have any questions or concerns. For a full list of video tutorials for FWE parts, check out this <a href="https://www.youtube.com/playlist?list=PLPyd_Uwy5f73F9oCC3NbIivtGe0p8fH4d">youtube playlist</a>.</p>
<p>The post <a href="https://www.hatcodirect.com/how-to-replace-the-controller-on-hhs-units/">How to Replace the Controller on HHS Units</a> appeared first on <a href="https://www.hatcodirect.com">OEM Parts for Hatco Equipment | Hatco Trade Direct Parts</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>How to Install a Retrofit Relay Kit (Z-500-1056) in FWE MTU Series Cabinets</title>
		<link>https://www.hatcodirect.com/how-to-install-a-retrofit-relay-kit-z-500-1056-in-fwe-mtu-series-cabinets/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Tue, 26 Sep 2023 16:50:55 +0000</pubDate>
				<category><![CDATA[MTU Series]]></category>
		<category><![CDATA[Service & Part Replacement]]></category>
		<guid isPermaLink="false">https://www.hatcodirect.com/?p=21987</guid>

					<description><![CDATA[<p>A step-by-step tutorial for Installing a Retrofit Relay Kit In the food service industry, equipment breakdowns can cause major disruptions to operations leading to lost revenue and frustrated customers. FWEParts step-by-step tutorials are here to provide easy-to-follow guides that will help you can get your equipment back into operation as quickly as possible. In this [&#8230;]</p>
<p>The post <a href="https://www.hatcodirect.com/how-to-install-a-retrofit-relay-kit-z-500-1056-in-fwe-mtu-series-cabinets/">How to Install a Retrofit Relay Kit (Z-500-1056) in FWE MTU Series Cabinets</a> appeared first on <a href="https://www.hatcodirect.com">OEM Parts for Hatco Equipment | Hatco Trade Direct Parts</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<h2 class="wp-block-heading">A step-by-step tutorial for Installing a Retrofit Relay Kit </h2>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<p class="wp-block-paragraph">In the food service industry, equipment breakdowns can cause major disruptions to operations leading to lost revenue and frustrated customers. FWEParts step-by-step tutorials are here to provide easy-to-follow guides that will help you can get your equipment back into operation as quickly as possible. In this article, we will introduce a service video that provides a step-by-step tutorial to easily Troubleshoot an ELAN (T-STAT ELE) Control Board used on FWE units. If you are still experiencing issues with this, or any other part, please do not hesitate to reach out via phone at <a href="tel:16158053270">1-615-805-3270</a> or email at <a href="mailto:service@hatcodirect.com">service@hatcodirect.com</a> if you have any questions or concerns.</p>



<figure class="wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio"><div class="wp-block-embed__wrapper">
<iframe title="FWEParts | MTU Series | How to Install a Retrofit Relay Kit (Z-500-1056) in FWE MTU Series Cabinets" width="1140" height="641" src="https://www.youtube.com/embed/jcFRRZaHx-w?feature=oembed&#038;enablejsapi=1&#038;origin=https://www.hatcodirect.com" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" allowfullscreen></iframe>
</div></figure>



<h2 class="wp-block-heading">Part Covered in this Tutorial</h2>



<ul class="wp-block-list">
<li><a href="https://www.hatcodirect.com/part/z-500-1056/">Z-500-1056</a></li>
</ul>



<h2 class="wp-block-heading">Tools Needed</h2>



<ul class="wp-block-list">
<li>Driver Drill with #2 Phillips Bit</li>



<li>1/4&#8243; Nut Driver</li>
</ul>



<h2 class="wp-block-heading">Steps</h2>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=jcFRRZaHx-w&amp;t=0s">0:00</a> | Introduction</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=jcFRRZaHx-w&amp;t=11s">0:11</a> | Step 1 &#8211; Unplug unit and remove from service</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=jcFRRZaHx-w&amp;t=16s">0:16</a> | Step 2 &#8211; Open the packaging and locate relay assembly with included wiring harness and wiring diagram. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=jcFRRZaHx-w&amp;t=22s">0:22</a> | Step 3 &#8211; Remove side panel from the unity and locate terminal block and element.</p>



<p class="wp-block-paragraph"> <a href="https://www.youtube.com/watch?v=jcFRRZaHx-w&amp;t=29s">0:29</a> | Step 4 &#8211; Remove existing wire (left side) from the element terminal and remove the terminal block,. Discard Wire. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=jcFRRZaHx-w&amp;t=36s">0:36</a> | Step 5 &#8211; Install the new wire (Wire #33) from the relay coil to the terminal block position #3 where the wire was removed from in step 4. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=jcFRRZaHx-w&amp;t=43s">0:43</a> | Step 6 &#8211; Remove the existing red wire (Wire #4) from the element terminal (Right side) and install on the other side of the relay coil. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=jcFRRZaHx-w&amp;t=54s">0:54</a> | Step 7 &#8211; Install black wire (Wire #30) on the terminal block position #2 where the incoming line power from cord is connected. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=jcFRRZaHx-w&amp;t=69s">1:09</a> | Step 8 &#8211; Install white wire (Wire #34) on the terminal block position #4 where the incoming neutral line from the cord is connected. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=jcFRRZaHx-w&amp;t=78s">1:18</a> | Step 9 &#8211; Install the red wire (Wire #31) onto the right side element terminal. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=jcFRRZaHx-w&amp;t=84s">1:24</a> | Step 10 &#8211; Install White wire (Wire #32) onto the left side element terminal. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=jcFRRZaHx-w&amp;t=91s">1:31</a> | Step 11 &#8211; Route wiring so it does not interfere with rear fan blade on the motor. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=jcFRRZaHx-w&amp;t=99s">1:39</a> | Step 12 &#8211; Mount the relay to the bottom of the compartment with your choice of fastener. (Zip screws recommended) </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=jcFRRZaHx-w&amp;t=109s">1:49</a> | Step 13 &#8211; Restore power and test the unit for operationality. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=jcFRRZaHx-w&amp;t=115s">1:55</a> | Step 14 &#8211; Reinstall side panel and return unit to service.</p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<p class="wp-block-paragraph">In the food service industry, equipment breakdowns can be disruptive and costly. That&#8217;s why FWEParts is committed to providing step-by-step tutorials that make equipment repairs a breeze. If you&#8217;re facing issues with installing retrofit kits, or anything other issue you may face, our service video offers a comprehensive guide to easily troubleshoot it using common tools. We&#8217;re here to support you every step of the way, so don&#8217;t hesitate to reach out to us at <a href="tel:1-615-805-3270">1-615-805-3270</a> or <a href="mailto:service@hatcodirect.com">service@hatcodirect.com</a> if you have any questions or concerns. For a full list of video tutorials for FWE parts, check out this <a href="https://www.youtube.com/playlist?list=PLPyd_Uwy5f73F9oCC3NbIivtGe0p8fH4d">youtube playlist</a>.</p>
<p>The post <a href="https://www.hatcodirect.com/how-to-install-a-retrofit-relay-kit-z-500-1056-in-fwe-mtu-series-cabinets/">How to Install a Retrofit Relay Kit (Z-500-1056) in FWE MTU Series Cabinets</a> appeared first on <a href="https://www.hatcodirect.com">OEM Parts for Hatco Equipment | Hatco Trade Direct Parts</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>How to Replace the Cavity Probe and Meat Probe Socket on FWE LCH Units</title>
		<link>https://www.hatcodirect.com/how-to-replace-the-cavity-probe-and-meat-probe-socket-on-fwe-lch-units/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Mon, 14 Aug 2023 19:07:28 +0000</pubDate>
				<category><![CDATA[LCH Series]]></category>
		<category><![CDATA[LCH-G2 Series]]></category>
		<category><![CDATA[Service & Part Replacement]]></category>
		<category><![CDATA[Uncategorized]]></category>
		<guid isPermaLink="false">https://www.hatcodirect.com/?p=21985</guid>

					<description><![CDATA[<p>A step-by-step tutorial for Replacing the Elements within a Moisture-Temp Cabinet In the food service industry, equipment breakdowns can cause major disruptions to operations leading to lost revenue and frustrated customers. FWEParts step-by-step tutorials are here to provide easy-to-follow guides that will help you can get your equipment back into operation as quickly as possible. [&#8230;]</p>
<p>The post <a href="https://www.hatcodirect.com/how-to-replace-the-cavity-probe-and-meat-probe-socket-on-fwe-lch-units/">How to Replace the Cavity Probe and Meat Probe Socket on FWE LCH Units</a> appeared first on <a href="https://www.hatcodirect.com">OEM Parts for Hatco Equipment | Hatco Trade Direct Parts</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<h3 class="wp-block-heading">A step-by-step tutorial for Replacing the Elements within a Moisture-Temp Cabinet </h3>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<p class="wp-block-paragraph">In the food service industry, equipment breakdowns can cause major disruptions to operations leading to lost revenue and frustrated customers. FWEParts step-by-step tutorials are here to provide easy-to-follow guides that will help you can get your equipment back into operation as quickly as possible. In this article, we will introduce a service video that provides a step-by-step tutorial to easily replace the Cavity Probe and Meat Probe Socket used within FWE LCH units. If you are still experiencing issues with this, or any other part, please do not hesitate to reach out via phone at <a href="tel:16158053270">1-615-805-3270</a> or email at <a href="mailto:service@hatcodirect.com">service@hatcodirect.com</a> if you have any questions or concerns.</p>



<figure class="wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio"><div class="wp-block-embed__wrapper">
<iframe title="FWEParts | LCH-G2 Series | How to Replace the Cavity Probe and Meat Probe Socket" width="1140" height="641" src="https://www.youtube.com/embed/t6ybIbKfkTo?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" allowfullscreen></iframe>
</div></figure>



<h3 class="wp-block-heading">Parts Covered in this Tutorial</h3>



<ul class="wp-block-list">
<li> Cavity Probe |<a href="https://www.hatcodirect.com/part/prb-rtd/"> PRB RTD </a></li>



<li> Meat Probe | <a href="https://www.hatcodirect.com/part/prb-rtd-36/">PRB RTD 36 </a></li>
</ul>



<h3 class="wp-block-heading">Tools Needed</h3>



<ul class="wp-block-list">
<li>Driver Drill with #2 Phillips Bit</li>



<li>5/16&#8243; Nut Driver</li>



<li>1/4&#8243; Nut Driver</li>



<li>Pin Screwdriver</li>
</ul>



<h3 class="wp-block-heading">Steps</h3>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=t6ybIbKfkTo">0:00</a> &#8211; Introduction</p>



<p class="wp-block-paragraph"><strong>Replacing Cavity Probe</strong></p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=t6ybIbKfkTo&amp;t=20s">0:20</a> | Step 1: Remove the screws around the cover and see the cover aside. Open the unit and remove the racks and tray slides. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=t6ybIbKfkTo&amp;t=41s">0:41</a> | Step 2: Open the unit and locate the Cavity Probe on the left-hand side wall. Remove the two screws holding the probe in place. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=t6ybIbKfkTo&amp;t=52s">0:52</a> | Step 3: In the top of the unit, disconnect the Cavity Probe wires going to the control board, taking note of their location. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=t6ybIbKfkTo&amp;t=66s">1:06</a> | Step 4: Remove the old cavity probe and discard it. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=t6ybIbKfkTo&amp;t=73s">1:13</a> | Step 5: Guide new probe wires through the inside of the unit and grommet in the top side wall, up to the control board. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=t6ybIbKfkTo&amp;t=83s">1:23</a> | Step 6: Install the new Cavity Prove, mounting with the screws removed in Step 3. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=t6ybIbKfkTo&amp;t=93s">1:33</a> | Step 7: Connect the new probe wire to the control board. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=t6ybIbKfkTo&amp;t=99s">1:39</a> | Step 8: Restore power to the unit and test for operationality. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=t6ybIbKfkTo&amp;t=113s">1:53</a> | Step 9: Install the top cover and return the unit to service.</p>



<p class="wp-block-paragraph"><strong>Replacing Meat Probe Socket</strong></p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=t6ybIbKfkTo&amp;t=132s">2:12</a> | Step 1: Remove the screws around the cover and set the cover aside. Open the unit and remove racks and tray slides. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=t6ybIbKfkTo&amp;t=152s">2:32</a> | Step 2: Open the unit and locate the Meat Probe Socket and mounting bracket on the left-hand side wall. Remove the two screws holding the mounting bracket in place. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=t6ybIbKfkTo&amp;t=161s">2:41</a> | Step 3: In the top of the unit, disconnect the Probe Socket wires going to the control board, taking note of their location. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=t6ybIbKfkTo&amp;t=174s">2:54</a> | Step 4: Remove the mounting bracket and set it aside. Remove the old Probe Socket and discard it. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=t6ybIbKfkTo&amp;t=183s">3:03</a> | Step 5: Guide the new probe wires through the inside of the unit and grommet in the top side wall, up to the control board. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=t6ybIbKfkTo&amp;t=195s">3:15</a> | Step 6: Install the new Probe Socket in the mounting bracket and secure it with the screws removed in Step 3. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=t6ybIbKfkTo&amp;t=205s">3:25</a> | Step 7: Connect the new Probe Socket wires to the control board. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=t6ybIbKfkTo&amp;t=212s">3:32</a> | Step 8: Restore power to the unit and test for operationality. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=t6ybIbKfkTo&amp;t=225s">3:45</a> | Step 9: Install the top cover and return the unit to service.</p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<p class="wp-block-paragraph">In the food service industry, equipment breakdowns can be disruptive and costly. That&#8217;s why FWEParts is committed to providing step-by-step tutorials that make equipment repairs a breeze. If you&#8217;re facing issues replacing the Cavity Probe or Meat Probe Sockets, our service video offers a comprehensive guide to easily troubleshoot it using common tools. We&#8217;re here to support you every step of the way, so don&#8217;t hesitate to reach out to us at <a href="tel:1-615-805-3270">1-615-805-3270</a> or <a href="mailto:service@hatcodirect.com">service@hatcodirect.com</a> if you have any questions or concerns. For a full list of video tutorials for FWE parts, check out this <a href="https://www.youtube.com/playlist?list=PLPyd_Uwy5f73F9oCC3NbIivtGe0p8fH4d">youtube playlist</a>.</p>



<p class="wp-block-paragraph"></p>
<p>The post <a href="https://www.hatcodirect.com/how-to-replace-the-cavity-probe-and-meat-probe-socket-on-fwe-lch-units/">How to Replace the Cavity Probe and Meat Probe Socket on FWE LCH Units</a> appeared first on <a href="https://www.hatcodirect.com">OEM Parts for Hatco Equipment | Hatco Trade Direct Parts</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>How to Replace the Elements in FWE LCH-G2 Units</title>
		<link>https://www.hatcodirect.com/how-to-replace-the-elements-in-fwe-lch-g2-units/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Mon, 14 Aug 2023 18:17:33 +0000</pubDate>
				<category><![CDATA[LCH-G2 Series]]></category>
		<category><![CDATA[Service & Part Replacement]]></category>
		<guid isPermaLink="false">https://www.hatcodirect.com/?p=21979</guid>

					<description><![CDATA[<p>A step-by-step tutorial for Replacing the Elements in LCH-G2 Units In the food service industry, equipment breakdowns can cause major disruptions to operations leading to lost revenue and frustrated customers. FWEParts step-by-step tutorials are here to provide easy-to-follow guides that will help you can get your equipment back into operation as quickly as possible. In [&#8230;]</p>
<p>The post <a href="https://www.hatcodirect.com/how-to-replace-the-elements-in-fwe-lch-g2-units/">How to Replace the Elements in FWE LCH-G2 Units</a> appeared first on <a href="https://www.hatcodirect.com">OEM Parts for Hatco Equipment | Hatco Trade Direct Parts</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<h2 class="wp-block-heading">A step-by-step tutorial for Replacing the Elements in LCH-G2 Units</h2>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<p class="wp-block-paragraph">In the food service industry, equipment breakdowns can cause major disruptions to operations leading to lost revenue and frustrated customers. FWEParts step-by-step tutorials are here to provide easy-to-follow guides that will help you can get your equipment back into operation as quickly as possible. In this article, we will introduce a service video that provides a step-by-step tutorial to easily Replace the Heating Elements used on FWE LCH-G2 units. If you are still experiencing issues with this, or any other part, please do not hesitate to reach out via phone at <a href="tel:16158053270">1-615-805-3270</a> or email at <a href="mailto:service@hatcodirect.com">service@hatcodirect.com</a> if you have any questions or concerns</p>



<figure class="wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio"><div class="wp-block-embed__wrapper">
<iframe loading="lazy" title="FWEParts | LCH-G2 Series | How to Replace the Elements" width="1140" height="641" src="https://www.youtube.com/embed/mgYLJZcrNkw?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" allowfullscreen></iframe>
</div></figure>



<h2 class="wp-block-heading">Parts Covered in this Tutorial</h2>



<ul class="wp-block-list">
<li><a href="https://www.hatcodirect.com/part/el1500-240-lch/">EL1500-240-LCH</a></li>



<li><a href="https://www.hatcodirect.com/part/el1500-240/">EL1500-240</a></li>
</ul>



<h2 class="wp-block-heading">Tools Needed</h2>



<ul class="wp-block-list">
<li>Driver Drill with #2 Phillips Bit</li>



<li>5/16&#8243; Nut Driver</li>



<li>1/4&#8243; Nut Driver</li>



<li>11/16&#8243; Socket Wrench</li>
</ul>



<h2 class="wp-block-heading">Steps</h2>



<p class="wp-block-paragraph"><strong>Replacing Rear Element</strong></p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=mgYLJZcrNkw&amp;t=20s">0:20</a> | Step 1: Open the unit&#8217;s door and remove the racks, tray slides, drip pan, tray uprights, and bottom heat shield.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=mgYLJZcrNkw&amp;t=42s">0:42</a> | Step 2: Remove the back tunnel to expose the rear element. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=mgYLJZcrNkw&amp;t=50s">0:50</a> | Step 3: Remove the outside back panel and locate the element terminals (2 inside terminals). </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=mgYLJZcrNkw&amp;t=58s">0:58</a> | Step 4: Disconnect the element wire connections. Remove nuts and washers and pull out the element from inside the unit. Discard the old element. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=mgYLJZcrNkw&amp;t=75s">1:15</a> | Step 5: Install the new element through the inside unit around the blower fan, locking it in place with nuts and washers removed in step 4. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=mgYLJZcrNkw&amp;t=86s">1:26</a> | Step 6: Reconnect the element connections and reinstall the back tunnel. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=mgYLJZcrNkw&amp;t=95s">1:35</a> | Step 7: Restore power and test unit for operationality. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=mgYLJZcrNkw&amp;t=102s">1:42</a> | Step 8: Reinstall the outside back panel, heat shield, tray uprights, tray slides, drip pan, and racks. Return unit to service.</p>



<p class="wp-block-paragraph"><strong>Replacing Bottom Element</strong></p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=mgYLJZcrNkw&amp;t=127s">2:07</a> | Step 1: Open the unit&#8217;s door and remove the racks, tray slides, and drip pan. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=mgYLJZcrNkw&amp;t=144s">2:24</a> | Step 2: Remove tray uprights and heat shield to expose the bottom element and element strap. Remove the strap and set aside. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=mgYLJZcrNkw&amp;t=158s">2:38</a> | Step 3: Remove the outside back panel and locate the 2 outside element terminals. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=mgYLJZcrNkw&amp;t=166s">2:46</a> | Step 4: Disconnect the element wire connections. Remove the nuts and washers and pull out the element from inside the unit. Discard the old element. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=mgYLJZcrNkw&amp;t=179s">2:59</a> | Step 5: Install the new element through the inside of the unit, remounting the strap over the element with the screws removed in Step 2. Lock the element in place with the nuts and washers removed in Step 4. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=mgYLJZcrNkw&amp;t=195s">3:15</a> | Step 6: Reconnect the element wire connections. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=mgYLJZcrNkw&amp;t=203s">3:23</a> | Step 7: Restore power and test the unit for operationality. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=mgYLJZcrNkw&amp;t=210s">3:30</a> | Step 8: Reinstall the outside back panel, heat shield, tray uprights, tray slides, drip pan, and racks. Return unit to service</p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<p class="wp-block-paragraph">In the food service industry, equipment breakdowns can be disruptive and costly. That&#8217;s why FWEParts is committed to providing step-by-step tutorials that make equipment repairs a breeze. If you&#8217;re facing issues replacing the elements used within FWE LCH-G2 units, our service video offers a comprehensive guide to easily troubleshoot it using common tools. We&#8217;re here to support you every step of the way, so don&#8217;t hesitate to reach out to us at <a href="tel:1-615-805-3270">1-615-805-3270</a> or <a href="mailto:service@hatcodirect.com">service@hatcodirect.com</a> if you have any questions or concerns. For a full list of video tutorials for FWE parts, check out this <a href="https://www.youtube.com/playlist?list=PLPyd_Uwy5f73F9oCC3NbIivtGe0p8fH4d">youtube playlist</a>.</p>
<p>The post <a href="https://www.hatcodirect.com/how-to-replace-the-elements-in-fwe-lch-g2-units/">How to Replace the Elements in FWE LCH-G2 Units</a> appeared first on <a href="https://www.hatcodirect.com">OEM Parts for Hatco Equipment | Hatco Trade Direct Parts</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>How to Replace the M-Wave Control Board (CNTRL BRD LCH PRGM 240) in LCH-G2 Units</title>
		<link>https://www.hatcodirect.com/how-to-replace-the-m-wave-control-board-cntrl-brd-lch-prgm-240-in-lch-g2-units/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Mon, 14 Aug 2023 18:16:06 +0000</pubDate>
				<category><![CDATA[LCH-G2 Series]]></category>
		<category><![CDATA[Service & Part Replacement]]></category>
		<guid isPermaLink="false">https://www.hatcodirect.com/?p=21977</guid>

					<description><![CDATA[<p>A step-by-step tutorial for Replacing the Elements within a Moisture-Temp Cabinet In the food service industry, equipment breakdowns can cause major disruptions to operations leading to lost revenue and frustrated customers. FWEParts step-by-step tutorials are here to provide easy-to-follow guides that will help you can get your equipment back into operation as quickly as possible. [&#8230;]</p>
<p>The post <a href="https://www.hatcodirect.com/how-to-replace-the-m-wave-control-board-cntrl-brd-lch-prgm-240-in-lch-g2-units/">How to Replace the M-Wave Control Board (CNTRL BRD LCH PRGM 240) in LCH-G2 Units</a> appeared first on <a href="https://www.hatcodirect.com">OEM Parts for Hatco Equipment | Hatco Trade Direct Parts</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<h2 class="wp-block-heading">A step-by-step tutorial for Replacing the Elements within a Moisture-Temp Cabinet </h2>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<p class="wp-block-paragraph">In the food service industry, equipment breakdowns can cause major disruptions to operations leading to lost revenue and frustrated customers. FWEParts step-by-step tutorials are here to provide easy-to-follow guides that will help you can get your equipment back into operation as quickly as possible. In this article, we will introduce a service video that provides a step-by-step tutorial to easily replace the hot air element and water element used within FWE Moisture-Temp units. If you are still experiencing issues with this, or any other part, please do not hesitate to reach out via phone at <a href="tel:16158053270">1-615-805-3270</a> or email at <a href="mailto:service@hatcodirect.com">service@hatcodirect.com</a> if you have any questions or concerns.</p>



<figure class="wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio"><div class="wp-block-embed__wrapper">
<iframe loading="lazy" title="FWEParts | LCH-G2 Series | How to Replace the M-Wave Control Board (CNTRL BRD LCH PRGM 240)" width="1140" height="641" src="https://www.youtube.com/embed/MBJS5t3KBI8?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" allowfullscreen></iframe>
</div></figure>



<h2 class="wp-block-heading">Parts Covered in this Tutorial</h2>



<ul class="wp-block-list">
<li><a href="https://www.hatcodirect.com/part/cntrl-brd-lch-prgm/">CNTRL BRD LCH PRGRM 240</a></li>
</ul>



<h2 class="wp-block-heading">Tools Needed</h2>



<ul class="wp-block-list">
<li>Driver Drill with #2 Phillips Bit</li>



<li>5/16&#8243; Nut Driver</li>



<li>1/4&#8243; Nut Driver</li>



<li>Pin Screwdriver</li>
</ul>



<h2 class="wp-block-heading">Steps</h2>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=MBJS5t3KBI8&amp;t=0s">0:00</a> | Introduction</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=MBJS5t3KBI8&amp;t=17s">0:17</a> | Step 1: Remove the screws around the top cover, then remove the cover and set aside. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=MBJS5t3KBI8&amp;t=27s">0:27</a> | Step 2: Locate the control board inside the top of the unit. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=MBJS5t3KBI8&amp;t=1s">0:34</a> | Step 3: Disconnect all the wires attached to the control board, taking note of their locations. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=MBJS5t3KBI8&amp;t=53s">0:53</a> | Step 4: Locate and remove the 4 nuts that hold the control board in place. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=MBJS5t3KBI8&amp;t=66s">1:06</a> | Step 5: Remove the control board from the mounting screws. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=MBJS5t3KBI8&amp;t=72s">1:12</a> | Step 6: Install the new control board. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=MBJS5t3KBI8&amp;t=87s">1:27</a> | Step 7: Install the 4 nuts removed in Step 4 to secure the control board. Tighten so the button functions depress correctly, careful not to overtighten. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=MBJS5t3KBI8&amp;t=98s">1:38</a> | Step 8: Reconnect all the wires removed in Step 3 to the correct locations on the new board. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=MBJS5t3KBI8&amp;t=109s">1:49</a> | Step 9: Restore power and test the unit for operationality. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=MBJS5t3KBI8&amp;t=116s">1:56</a> | Step 10: Reinstall the top cover and fasten using the screw removed in Step 1. Return the unit to service.</p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<p class="wp-block-paragraph">In the food service industry, equipment breakdowns can be disruptive and costly. That&#8217;s why FWEParts is committed to providing step-by-step tutorials that make equipment repairs a breeze. If you&#8217;re facing issues replacing the hot air or water elements used within FWE Moisture Temp units, our service video offers a comprehensive guide to easily troubleshoot it using common tools. We&#8217;re here to support you every step of the way, so don&#8217;t hesitate to reach out to us at <a href="tel:1-615-805-3270">1-615-805-3270</a> or <a href="mailto:service@hatcodirect.com">service@hatcodirect.com</a> if you have any questions or concerns. For a full list of video tutorials for FWE parts, check out this <a href="https://www.youtube.com/playlist?list=PLPyd_Uwy5f73F9oCC3NbIivtGe0p8fH4d">youtube playlist</a>.</p>
<p>The post <a href="https://www.hatcodirect.com/how-to-replace-the-m-wave-control-board-cntrl-brd-lch-prgm-240-in-lch-g2-units/">How to Replace the M-Wave Control Board (CNTRL BRD LCH PRGM 240) in LCH-G2 Units</a> appeared first on <a href="https://www.hatcodirect.com">OEM Parts for Hatco Equipment | Hatco Trade Direct Parts</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>How to Change the Control Board Temperature Display and Control Lock Settings on FWE LCH Units</title>
		<link>https://www.hatcodirect.com/how-to-change-the-control-board-temperature-display-and-control-lock-settings-on-fwe-lch-units/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Wed, 09 Aug 2023 18:55:16 +0000</pubDate>
				<category><![CDATA[LCH Series]]></category>
		<category><![CDATA[LCH-G2 Series]]></category>
		<category><![CDATA[Service & Part Replacement]]></category>
		<category><![CDATA[Uncategorized]]></category>
		<guid isPermaLink="false">https://www.hatcodirect.com/?p=21983</guid>

					<description><![CDATA[<p>In the food service industry, equipment breakdowns can cause major disruptions to operations leading to lost revenue and frustrated customers. FWEParts step-by-step tutorials are here to provide easy-to-follow guides that will help you can get your equipment back into operation as quickly as possible. In this article, we will introduce a service video that provides [&#8230;]</p>
<p>The post <a href="https://www.hatcodirect.com/how-to-change-the-control-board-temperature-display-and-control-lock-settings-on-fwe-lch-units/">How to Change the Control Board Temperature Display and Control Lock Settings on FWE LCH Units</a> appeared first on <a href="https://www.hatcodirect.com">OEM Parts for Hatco Equipment | Hatco Trade Direct Parts</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<hr class="wp-block-separator has-alpha-channel-opacity"/>



<p class="wp-block-paragraph">In the food service industry, equipment breakdowns can cause major disruptions to operations leading to lost revenue and frustrated customers. FWEParts step-by-step tutorials are here to provide easy-to-follow guides that will help you can get your equipment back into operation as quickly as possible. In this article, we will introduce a service video that provides a step-by-step tutorial to easily change the control board temperature display and control lock settings on FWE LCH units. If you are still experiencing issues with this, or any other part, please do not hesitate to reach out via phone at <a href="tel:16158053270">1-615-805-3270</a> or email at <a href="mailto:service@hatcodirect.com">service@hatcodirect.com</a> if you have any questions or concerns.</p>



<figure class="wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio"><div class="wp-block-embed__wrapper">
<iframe loading="lazy" title="FWEParts | LCH-G2 Series | How to Change the Control Board Temp. Display &amp; Control Lock Settings" width="1140" height="641" src="https://www.youtube.com/embed/lgB8n1GTmbU?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" allowfullscreen></iframe>
</div></figure>



<h3 class="wp-block-heading">Parts Covered in this Tutorial</h3>



<ul class="wp-block-list">
<li>LCH-G2 FWE Models</li>
</ul>



<h3 class="wp-block-heading">Tools Needed</h3>



<ul class="wp-block-list">
<li>None</li>
</ul>



<h3 class="wp-block-heading">Steps</h3>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=lgB8n1GTmbU">0:00 </a>&#8211; Introduction</p>



<p class="wp-block-paragraph"><strong>Changing Control to Display Fahrenheit or Celsius</strong></p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=lgB8n1GTmbU&amp;t=12s">0:12</a> | Step 1: Hold down the Start/Cancel button while powering on the unit. </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=lgB8n1GTmbU&amp;t=18s">0:18</a> | Step 2: Turn the dial clockwise to select Fahrenheit or counterclockwise to select Celsius </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=lgB8n1GTmbU&amp;t=24s">0:24</a> | Step 3: Once the correct setting is selected, press the Start/Cancel button to save the selection.</p>



<p class="wp-block-paragraph"><strong>Control Lock Function</strong></p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=lgB8n1GTmbU&amp;t=30s">0:30</a> | Step 1: From idle &#8220;&#8212;-&#8221; Press and hold the Start/Cancel button for 10 seconds. Control will display the text &#8220;Loc&#8221; for 2 seconds with a 1-second audible beep. (NOTE: While controls are locked, only idle (&#8212;-), Start/Cancel, and presets buttons are accessible.) </p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=lgB8n1GTmbU&amp;t=69s">1:09</a> | Step 2: To unlock the controls, press and hold the Start/Cancel button for 10 seconds from idle &#8220;&#8212;-&#8220;. Control will display the text &#8220;Uloc&#8221; for 2 seconds with a 1-second audible beep.</p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<p class="wp-block-paragraph">In the food service industry, equipment breakdowns can be disruptive and costly. That&#8217;s why FWEParts is committed to providing step-by-step tutorials that make equipment repairs a breeze. If you&#8217;re facing issues changing the control board temperature display, or control lock settings, our service video offers a comprehensive guide to easily troubleshoot it using common tools. We&#8217;re here to support you every step of the way, so don&#8217;t hesitate to reach out to us at <a href="tel:16158053270">1-615-805-3270</a> or <a href="mailto:service@hatcodirect.com">service@hatcodirect.com</a> if you have any questions or concerns. For a full list of video tutorials for FWE parts, check out this <a href="https://www.youtube.com/playlist?list=PLPyd_Uwy5f73F9oCC3NbIivtGe0p8fH4d">youtube playlist</a>.</p>
<p>The post <a href="https://www.hatcodirect.com/how-to-change-the-control-board-temperature-display-and-control-lock-settings-on-fwe-lch-units/">How to Change the Control Board Temperature Display and Control Lock Settings on FWE LCH Units</a> appeared first on <a href="https://www.hatcodirect.com">OEM Parts for Hatco Equipment | Hatco Trade Direct Parts</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>How to Replace Heat and Water Elements in FWE Moisture-Temp Cabinets (MTU &#038;PHU) Series</title>
		<link>https://www.hatcodirect.com/how-to-replace-heat-and-water-elements-in-fwe-moisture-temp-cabinets-mtu-phu-series/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Wed, 17 May 2023 16:48:35 +0000</pubDate>
				<category><![CDATA[MTU Series]]></category>
		<category><![CDATA[PHU Series]]></category>
		<category><![CDATA[Service & Part Replacement]]></category>
		<category><![CDATA[Videos]]></category>
		<guid isPermaLink="false">https://www.hatcodirect.com/?p=21487</guid>

					<description><![CDATA[<p>A step-by-step tutorial for Replacing the Elements within a Moisture-Temp Cabinet In the food service industry, equipment breakdowns can cause major disruptions to operations leading to lost revenue and frustrated customers. FWEParts step-by-step tutorials are here to provide easy-to-follow guides that will help you can get your equipment back into operation as quickly as possible. [&#8230;]</p>
<p>The post <a href="https://www.hatcodirect.com/how-to-replace-heat-and-water-elements-in-fwe-moisture-temp-cabinets-mtu-phu-series/">How to Replace Heat and Water Elements in FWE Moisture-Temp Cabinets (MTU &#038;PHU) Series</a> appeared first on <a href="https://www.hatcodirect.com">OEM Parts for Hatco Equipment | Hatco Trade Direct Parts</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<h2 class="wp-block-heading">A step-by-step tutorial for Replacing the Elements within a Moisture-Temp Cabinet </h2>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<p class="wp-block-paragraph">In the food service industry, equipment breakdowns can cause major disruptions to operations leading to lost revenue and frustrated customers. FWEParts step-by-step tutorials are here to provide easy-to-follow guides that will help you can get your equipment back into operation as quickly as possible. In this article, we will introduce a service video that provides a step-by-step tutorial to easily replace the hot air element and water element used within FWE Moisture-Temp units. If you are still experiencing issues with this, or any other part, please do not hesitate to reach out via phone at <a href="tel:16158053270">1-615-805-3270</a> or email at <a href="mailto:service@hatcodirect.com">service@hatcodirect.com</a> if you have any questions or concerns.</p>



<figure class="wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio"><div class="wp-block-embed__wrapper">
<iframe loading="lazy" title="How to Replace Heat and Water Elements in FWE Moisture-Temp Cabinets. (MTU &amp; PHU Series)" width="1140" height="641" src="https://www.youtube.com/embed/fwfXUdXOdcA?feature=oembed&#038;enablejsapi=1&#038;origin=https://www.hatcodirect.com" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" allowfullscreen></iframe>
</div></figure>



<h2 class="wp-block-heading">Parts Covered in this Tutorial</h2>



<ul class="wp-block-list">
<li><a href="https://www.hatcodirect.com/part/el1250-120-ht/">EL1250-120-HT | Hot Air</a></li>



<li><a href="https://www.hatcodirect.com/part/el350-120-a16/">EL350-120-A16 | Water</a></li>
</ul>



<h2 class="wp-block-heading">Tools Needed</h2>



<ul class="wp-block-list">
<li>Driver Drill with #2 Phillips Bit</li>



<li>5/16&#8243; Nut Driver</li>



<li>1/4&#8243; Nut Driver</li>



<li>11/16&#8243; Socket Wrench</li>
</ul>



<h2 class="wp-block-heading">Steps</h2>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=fwfXUdXOdcA&amp;t=0s">0:00</a> &#8211; Introduction</p>



<p class="wp-block-paragraph"><strong>Replacing Hot Air Element</strong></p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=fwfXUdXOdcA&amp;t=18s">0:18</a> | Step 1: Open the unit and remove the heart tunnel assembly exposing the element and blower housing.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=fwfXUdXOdcA&amp;t=27s">0:27</a> | Step 2: Remove the side panel and locate the element.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=fwfXUdXOdcA&amp;t=35s">0:35</a> | Step 3: Disconnect the element connections and remove the element by taking off the nuts and washers. Pull the element out from the blower housing and discard it.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=fwfXUdXOdcA&amp;t=55s">0:55</a> | Step 4: Install the new element through the blower housing, locking it in place with the nuts and washers used in Step 3.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=fwfXUdXOdcA&amp;t=71s">1:11</a> | Step 5: Reconnect the element connections.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=fwfXUdXOdcA&amp;t=77s">1:17</a> | Step 6: Restore power and test the unit for operationality.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=fwfXUdXOdcA&amp;t=84s">1:24</a> | Step 7: Reinstall the side panel and heat tunnel assembly. Return unit to service.</p>



<p class="wp-block-paragraph"><strong>Replacing the Water Element</strong></p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=fwfXUdXOdcA&amp;t=92s">1:32</a> | Step 1: Open the unit and remove the heat tunnel assembly. Remove the water pan from the bottom of the unit.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=fwfXUdXOdcA&amp;t=106s">1:46</a> | Step 2: Locate the element under the water pan, Remove the two screws securing the element in place.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=fwfXUdXOdcA&amp;t=113s">1:53</a> | Step 3: Pull the element out and remove the wire connections from the element terminals. Discard the old element.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=fwfXUdXOdcA&amp;t=122s">2:02</a> | Step 4: Install wire connection onto the new element terminals.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=fwfXUdXOdcA&amp;t=129s">2:09</a> | Step 5: Push the new element back into place, aligning the gasket with the back plate. Secure with screws that were removed in Step 2.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=fwfXUdXOdcA&amp;t=135s">2:15</a> | Step 6: Reinstall the water pan and fill it with water. Restore power and test unit for operationality.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=fwfXUdXOdcA&amp;t=146s">2:26</a> | Step 7: Reinstall the heat tunnel assembly and return the unit to service.</p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<p class="wp-block-paragraph">In the food service industry, equipment breakdowns can be disruptive and costly. That&#8217;s why FWEParts is committed to providing step-by-step tutorials that make equipment repairs a breeze. If you&#8217;re facing issues replacing the hot air or water elements used within FWE Moisture Temp units, our service video offers a comprehensive guide to easily troubleshoot it using common tools. We&#8217;re here to support you every step of the way, so don&#8217;t hesitate to reach out to us at 1-615-805-3270 or <a href="mailto:service@hatcodirect.com">service@hatcodirect.com</a> if you have any questions or concerns. For a full list of video tutorials for FWE parts, check out this <a href="https://www.youtube.com/playlist?list=PLPyd_Uwy5f73F9oCC3NbIivtGe0p8fH4d">youtube playlist</a>.</p>
<p>The post <a href="https://www.hatcodirect.com/how-to-replace-heat-and-water-elements-in-fwe-moisture-temp-cabinets-mtu-phu-series/">How to Replace Heat and Water Elements in FWE Moisture-Temp Cabinets (MTU &#038;PHU) Series</a> appeared first on <a href="https://www.hatcodirect.com">OEM Parts for Hatco Equipment | Hatco Trade Direct Parts</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>How to Replace the Motor in FWE Moisture-Temp Cabinets (MTU &#038; PHU Series)</title>
		<link>https://www.hatcodirect.com/how-to-replace-the-motor-in-fwe-moisture-temp-cabinets-mtu-phu-series/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Mon, 15 May 2023 20:25:48 +0000</pubDate>
				<category><![CDATA[MTU Series]]></category>
		<category><![CDATA[PHU Series]]></category>
		<category><![CDATA[Service & Part Replacement]]></category>
		<category><![CDATA[Videos]]></category>
		<guid isPermaLink="false">https://www.hatcodirect.com/?p=21476</guid>

					<description><![CDATA[<p>A step-by-step tutorial for Replacing the Motor in FWE Moisture-Temp Cabinets In the food service industry, equipment breakdowns can cause major disruptions to operations leading to lost revenue and frustrated customers. FWEParts step-by-step tutorials are here to provide easy-to-follow guides that will help you can get your equipment back into operation as quickly as possible. [&#8230;]</p>
<p>The post <a href="https://www.hatcodirect.com/how-to-replace-the-motor-in-fwe-moisture-temp-cabinets-mtu-phu-series/">How to Replace the Motor in FWE Moisture-Temp Cabinets (MTU &#038; PHU Series)</a> appeared first on <a href="https://www.hatcodirect.com">OEM Parts for Hatco Equipment | Hatco Trade Direct Parts</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<h2 class="wp-block-heading">A step-by-step tutorial for Replacing the Motor in FWE Moisture-Temp Cabinets</h2>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<p class="wp-block-paragraph">In the food service industry, equipment breakdowns can cause major disruptions to operations leading to lost revenue and frustrated customers. FWEParts step-by-step tutorials are here to provide easy-to-follow guides that will help you can get your equipment back into operation as quickly as possible. In this article, we will introduce a service video that provides a step-by-step tutorial to easily replace the motor used on FWE Moisture-Temp Cabinets(MTU and PHU Series). If you are still experiencing issues with this, or any other part, please do not hesitate to reach out via phone at <a href="tel:16158053270">1-615-805-3270</a> or email at <a href="mailto:service@hatcodirect.com">service@hatcodirect.com</a> if you have any questions or concerns.</p>



<figure class="wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio"><div class="wp-block-embed__wrapper">
<iframe loading="lazy" title="How to Replace the Motor (Z-600-6151) in FWE Moisture-Temp Cabinets. (MTU &amp; PHU Series)" width="1140" height="641" src="https://www.youtube.com/embed/uoOIfzFE8dw?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" allowfullscreen></iframe>
</div></figure>



<h2 class="wp-block-heading">Parts Covered in this Tutorial</h2>



<ul class="wp-block-list">
<li><a href="https://www.hatcodirect.com/part/z-600-6151/">Z-600-6151</a></li>
</ul>



<h2 class="wp-block-heading">Tools Needed</h2>



<ul class="wp-block-list">
<li>Driver Drill with #2 Phillips Bit</li>



<li>5/16&#8243; Nut Driver</li>



<li>1/4&#8243; Nut Driver</li>



<li>11/16&#8243; Socket Wrench</li>



<li>Allen Key Set</li>
</ul>



<h2 class="wp-block-heading">Steps</h2>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=uoOIfzFE8dw&amp;t=0s">0:00</a> | Introduction</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=uoOIfzFE8dw&amp;t=17s">0:17</a> | Step 1: Open the unit and remove the heart tunnel assembly exposing the element and blower housing.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=uoOIfzFE8dw&amp;t=24s">0:24</a> | Step 2: Remove the side panel and locate the motor assembly.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=uoOIfzFE8dw&amp;t=31s">0:31</a> | Step 3: Remove the motor connections at the terminal block, making note of their positions.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=uoOIfzFE8dw&amp;t=38s">0:38</a> | Step 4: Disconnect the element connections and remove the element by taking off the nuts and washers and pulling it out from the blower housing.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=uoOIfzFE8dw&amp;t=59s">0:59</a> | Step 5: Remove the bolts holding the blower housing to the sidewall and set them aside.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=uoOIfzFE8dw&amp;t=67s">1:07</a> | Step 6: Locate the set screw on the fan blade. Loosen and remove the fan blade from the motor shaft.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=uoOIfzFE8dw&amp;t=75s">1:15</a> | Step 7: In the access panel, remove the bolts holding the motor in place and pull the motor assembly out.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=uoOIfzFE8dw&amp;t=85s">1:25</a> | Step 8: Locate the set screw for the rear fan blade. Loosen and remove the fan blade from the motor shaft.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=uoOIfzFE8dw&amp;t=92s">1:32</a> | Step 9: Install the rear fan blade on the new motor, locking it in place with the set screw.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=uoOIfzFE8dw&amp;t=98s">1:38</a> | Step 10: Install the new motor, using the bolts from Step 7 to secure it in place.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=uoOIfzFE8dw&amp;t=107s">1:47</a> | Step 11: Inside the unit, install the front blade onto the motor shaft, locking it in place with the set screw. (Ensure the blade spins free and clear of obstruction)</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=uoOIfzFE8dw&amp;t=114s">1:54</a> | Step 12: Remount the blower housing with the bolts used in Step 5.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=uoOIfzFE8dw&amp;t=123s">2:03</a> | Step 13: Reinstall the Element through the blower housing, locking it in place with the nuts used in Step 4.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=uoOIfzFE8dw&amp;t=138s">2:18</a> | Step 14: Reconnect the element connections.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=uoOIfzFE8dw&amp;t=145s">2:25</a> | Step 15: Reconnect the motor connections to the terminal block, making sure the wiring is clear of the rear blade.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=uoOIfzFE8dw&amp;t=156s">2:36</a> | Step 16: Restore the power and test the unit for operationality.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=uoOIfzFE8dw&amp;t=163s">2:43</a> | Step 17: Reinstall the side panel and heat tunnel assembly, then return the unit to service.</p>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<p class="wp-block-paragraph">In the food service industry, equipment breakdowns can be disruptive and costly. That&#8217;s why FWEParts is committed to providing step-by-step tutorials that make equipment repairs a breeze. If you&#8217;re facing issues with the motor used in Moisture-Temp FWE units, our service video offers a comprehensive guide to easily troubleshoot it using common tools. We&#8217;re here to support you every step of the way, so don&#8217;t hesitate to reach out to us at 1-615-805-3270 or <a href="mailto:service@hatcodirect.com">service@hatcodirect.com</a> if you have any questions or concerns. For a full list of video tutorials for FWE parts, check out this <a href="https://www.youtube.com/playlist?list=PLPyd_Uwy5f73F9oCC3NbIivtGe0p8fH4d">youtube playlist</a>.</p>
<p>The post <a href="https://www.hatcodirect.com/how-to-replace-the-motor-in-fwe-moisture-temp-cabinets-mtu-phu-series/">How to Replace the Motor in FWE Moisture-Temp Cabinets (MTU &#038; PHU Series)</a> appeared first on <a href="https://www.hatcodirect.com">OEM Parts for Hatco Equipment | Hatco Trade Direct Parts</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>How to Troubleshoot an ELAN (T-STAT ELE) Control Board for FWE Equipment</title>
		<link>https://www.hatcodirect.com/how-to-troubleshoot-an-elan-t-stat-ele-control-board-for-fwe-equipment/</link>
		
		<dc:creator><![CDATA[]]></dc:creator>
		<pubDate>Mon, 15 May 2023 16:32:37 +0000</pubDate>
				<category><![CDATA[Service & Part Replacement]]></category>
		<category><![CDATA[Videos]]></category>
		<guid isPermaLink="false">https://www.hatcodirect.com/?p=21465</guid>

					<description><![CDATA[<p>A step-by-step tutorial for Troubleshooting an ELAN Control Board In the food service industry, equipment breakdowns can cause major disruptions to operations leading to lost revenue and frustrated customers. FWEParts step-by-step tutorials are here to provide easy-to-follow guides that will help you can get your equipment back into operation as quickly as possible. In this [&#8230;]</p>
<p>The post <a href="https://www.hatcodirect.com/how-to-troubleshoot-an-elan-t-stat-ele-control-board-for-fwe-equipment/">How to Troubleshoot an ELAN (T-STAT ELE) Control Board for FWE Equipment</a> appeared first on <a href="https://www.hatcodirect.com">OEM Parts for Hatco Equipment | Hatco Trade Direct Parts</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<h2 class="wp-block-heading">A step-by-step tutorial for Troubleshooting an ELAN Control Board</h2>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<p class="wp-block-paragraph">In the food service industry, equipment breakdowns can cause major disruptions to operations leading to lost revenue and frustrated customers. FWEParts step-by-step tutorials are here to provide easy-to-follow guides that will help you can get your equipment back into operation as quickly as possible. In this article, we will introduce a service video that provides a step-by-step tutorial to easily Troubleshoot an ELAN (T-STAT ELE) Control Board used on FWE units. If you are still experiencing issues with this, or any other part, please do not hesitate to reach out via phone at <a href="tel:16158053270">1-615-805-3270</a> or email at <a href="mailto:service@hatcodirect.com">service@hatcodirect.com</a> if you have any questions or concerns.</p>



<figure class="wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio"><div class="wp-block-embed__wrapper">
<iframe loading="lazy" title="FWEParts | How to Troubleshoot an ELAN (T-STAT ELE) Control Board for FWE units." width="1140" height="641" src="https://www.youtube.com/embed/dHM_94IwhGM?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" allowfullscreen></iframe>
</div></figure>



<h2 class="wp-block-heading">Parts Covered in this Tutorial</h2>



<ul class="wp-block-list">
<li><a href="https://www.hatcodirect.com/part/t-stat-ele-2/">T-STAT ELE 2</a></li>



<li><a href="https://www.hatcodirect.com/part/t-stat-ele-h/">T-STAT ELE H</a></li>



<li><a href="https://www.hatcodirect.com/part/t-stat-ele-h2/">T-STAT ELE H2</a></li>



<li><a href="https://www.hatcodirect.com/part/t-stat-ele-h2-np/">T-STAT ELE H2 NP</a></li>



<li><a href="https://www.hatcodirect.com/part/t-stat-ele-moist-2/">T-STAT ELE MOIST 2</a></li>
</ul>



<h2 class="wp-block-heading">Tools Needed</h2>



<ul class="wp-block-list">
<li>Driver Drill with #2 Phillips Bit</li>



<li>5/16&#8243; Nuts Driver</li>
</ul>



<h2 class="wp-block-heading">Steps</h2>



<p class="wp-block-paragraph"><strong>Checking Dip Switch Setting</strong></p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=dHM_94IwhGM&amp;t=22s">0:22</a> | Step 1: Remove the top cover screws and set the cover aside.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=dHM_94IwhGM&amp;t=28s">0:28</a> | Step 2: Locate the control board inside the top of the unit.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=dHM_94IwhGM&amp;t=35s">0:35</a> | Step 3: Locate the dip switches on the back side of the control board.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=dHM_94IwhGM&amp;t=41s">0:41</a> | Step 4: Ensure the correct dip switch setting for the unit is set.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=dHM_94IwhGM&amp;t=58s">0:58</a> | Step 5: Power on the unit and test the operation of the temperature range, temp recall button, and low temp alarm button.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=dHM_94IwhGM&amp;t=70s">1:10</a> | Step 6: Once operationality is confirmed, reinstall the top cover with the screws removed in step 1 and return the unit to service.</p>



<p class="wp-block-paragraph"><strong>User Offset Temperature Adjustment</strong></p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=dHM_94IwhGM&amp;t=79s">1:19</a> | Step 1: Rotate the knob to the off position. Press and hold the &#8220;Temp Recall&#8221; key for 10 seconds until the display reads &#8220;Ofst&#8221;.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=dHM_94IwhGM&amp;t=102s">1:42</a> | Step 2: Rotate the knob to desired offset setting. Example: To make the unit 10° colder, rotate it to 10°F.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=dHM_94IwhGM&amp;t=108s">1:48</a> | Step 3: Press &#8220;Temp Recall&#8221; to accept the new offset. (After 5 seconds without pressing, the unit will revert to the previous temperature settings)</p>



<p class="wp-block-paragraph"><strong>Temperature Lock</strong></p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=dHM_94IwhGM&amp;t=113s">1:53</a> | Step 1: Rotate the knob to the desired temperature setting.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=dHM_94IwhGM&amp;t=124s">2:04</a> | Step 2: Press the &#8220;Temp Recall&#8221; button 3 times in 3 seconds. (Control will beep)</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=dHM_94IwhGM&amp;t=129s">2:09</a>| Step 3: Press and hold the &#8220;Temp Recall&#8221; button for 30 seconds. After 30 seconds, the display will show &#8220;Loc&#8221; and &#8220;tep&#8221; in succession. The dot displayed in the upper left sign also that the temperature setting is locked. To unlock the temperature setting, repeat Steps 1 &#8211; 3.</p>



<p class="wp-block-paragraph"><strong>Changing Temperature Display from °F to °C</strong></p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=dHM_94IwhGM&amp;t=147s">2:27</a> | Step 1: Rotate the knob to the off position and flip the power switch to the &#8220;off&#8221; position.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=dHM_94IwhGM&amp;t=160s">2:40</a> | Step 2: While pressing and holding the &#8220;Temp Recall&#8221; button, flip the power switch to the &#8220;on&#8221; position. The display will show the desired temperature unit. To change back to °F, repeat steps 1 and 2.</p>



<p class="wp-block-paragraph"><strong>Adjusting Low Temp Alarm</strong></p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=dHM_94IwhGM&amp;t=180s">3:00</a> | Step 1: Rotate the knob to the off position. Press and hold the &#8220;Low Temp Alarm&#8221; button for 6 seconds. The display will show &#8220;LtA&#8221; and flash the Low Temp Alarm setting. (Off will be displayed if not previously set)</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=dHM_94IwhGM&amp;t=201s">3:21</a> | Step 2: Rotate the knob to the desired temperature setting. Turn below the minimum setting for the unit to turn off.</p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=dHM_94IwhGM&amp;t=210s">3:30</a> | Step 3: Once the desired Low Temp Alarm setting is shown, press the &#8220;Low Temp Alarm&#8221; button to accept.</p>



<p class="wp-block-paragraph"><strong>Changing Display form Set Temperature to Actual Temperature</strong></p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=dHM_94IwhGM&amp;t=220s">3:40</a> | Step 1: Factory default displays the &#8220;Set Point Temperature.&#8221; To Display the Actual Temperature, press and hold the &#8220;Temp Recall button for 3 seconds. The display will show &#8220;Act&#8221;. Press the &#8220;Temp Recall&#8221; button will now show the &#8220;Set Point Temperature.&#8221; Press and hold the &#8220;Temp Recall&#8221; button again to change the display back to the &#8220;Set Point&#8221; temperature.</p>



<p class="wp-block-paragraph"><strong>Service Error Codes</strong></p>



<p class="wp-block-paragraph"><a href="https://www.youtube.com/watch?v=dHM_94IwhGM&amp;t=242s">4:02</a> | View various error codes</p>



<figure class="wp-block-table"><table class="has-fixed-layout"><tbody><tr><td class="has-text-align-center" data-align="center"><strong>FWE Error Code Display</strong></td><td class="has-text-align-center" data-align="center"><strong>Error Description</strong></td><td class="has-text-align-center" data-align="center"><strong>Error Definition Comments</strong></td><td class="has-text-align-center" data-align="center"><strong>Control Response</strong></td><td class="has-text-align-center" data-align="center"><strong>Reset</strong></td></tr><tr><td class="has-text-align-center" data-align="center"><strong>E-10</strong></td><td class="has-text-align-center" data-align="center">Sensor 0 Shorted</td><td class="has-text-align-center" data-align="center">Sensor short determined</td><td class="has-text-align-center" data-align="center"><strong>Control:</strong> Relay OFF<br><strong>Display:</strong> Flash error code<br><strong>Beeper:</strong> Error beep</td><td class="has-text-align-center" data-align="center">Auto-reset when the <br>sensor short is resolved.</td></tr><tr><td class="has-text-align-center" data-align="center"><strong>E-11</strong></td><td class="has-text-align-center" data-align="center">Sensor 0 Open</td><td class="has-text-align-center" data-align="center">Resistance >3000 ohm <br>(sensor not connected)</td><td class="has-text-align-center" data-align="center"><strong>Control:</strong> Relay OFF<br><strong>Display:</strong> Flash error code<br><strong>Beeper:</strong> Error beep</td><td class="has-text-align-center" data-align="center">Auto-reset when the <br>the good probe is attached. (i.e. valid reading)</td></tr><tr><td class="has-text-align-center" data-align="center"><strong>E-30</strong></td><td class="has-text-align-center" data-align="center">Under Temperature</td><td class="has-text-align-center" data-align="center">25°F under Set Point Temperature for 90 Minutes</td><td class="has-text-align-center" data-align="center">Control: Function Normal<br>Display: Flash error code<br>Beeper: Error beep</td><td class="has-text-align-center" data-align="center">Auto-reset when the temp rises above the Under Temp alarm condition.</td></tr><tr><td class="has-text-align-center" data-align="center"><strong>E-31</strong></td><td class="has-text-align-center" data-align="center">Over Temperature</td><td class="has-text-align-center" data-align="center">OVEN: 145°F over max temp range for the model. no delay.</td><td class="has-text-align-center" data-align="center"><strong>Control:</strong> Relay OFF<br><strong>Display:</strong> Flash error code<br><strong>Beeper:</strong> Error beep</td><td class="has-text-align-center" data-align="center">Auto-reset when the temperature &lt;145°F over max temp range.</td></tr><tr><td class="has-text-align-center" data-align="center"><strong>E-38</strong></td><td class="has-text-align-center" data-align="center">Internal Software Error</td><td class="has-text-align-center" data-align="center">Internal Software Error</td><td class="has-text-align-center" data-align="center"><strong>Control:</strong> Relay OFF<br><strong>Display:</strong> Flash error code<br><strong>Beeper:</strong> Error beep</td><td class="has-text-align-center" data-align="center">Call Factory</td></tr><tr><td class="has-text-align-center" data-align="center"><strong>E-39</strong></td><td class="has-text-align-center" data-align="center">Sensor Error</td><td class="has-text-align-center" data-align="center">Board level RTD temp circuit hardware error</td><td class="has-text-align-center" data-align="center"><strong>Control:</strong> Relay OFF<br><strong>Display:</strong> Flash error code<br><strong>Beeper:</strong> Error beep</td><td class="has-text-align-center" data-align="center">Call Factory</td></tr><tr><td class="has-text-align-center" data-align="center"><strong>E-70</strong></td><td class="has-text-align-center" data-align="center">Configuration Connector Error (Dip Switch)</td><td class="has-text-align-center" data-align="center">Dip switch error: no set to model or invalid model</td><td class="has-text-align-center" data-align="center"><strong>Control:</strong> Relay OFF<br><strong>Display:</strong> Flash error code<br><strong>Beeper:</strong> Error beep</td><td class="has-text-align-center" data-align="center">Correct Dip switch. Turn control OFF, then ON.</td></tr><tr><td class="has-text-align-center" data-align="center"><strong>E-83</strong></td><td class="has-text-align-center" data-align="center">EEPROM Error</td><td class="has-text-align-center" data-align="center">Bad checksum</td><td class="has-text-align-center" data-align="center"><strong>Control:</strong> Relay OFF<br><strong>Display:</strong> Flash error code<br><strong>Beeper:</strong> Error beep</td><td class="has-text-align-center" data-align="center">Reset by performing calibration.</td></tr><tr><td class="has-text-align-center" data-align="center"><strong>E-90</strong></td><td class="has-text-align-center" data-align="center">Key Shorted</td><td class="has-text-align-center" data-align="center">Any key > 1 min shorted</td><td class="has-text-align-center" data-align="center"><strong>Control:</strong> Relay OFF<br><strong>Display:</strong> Flash error code<br><strong>Beeper:</strong> Error beep</td><td class="has-text-align-center" data-align="center">Reset when key no longer shorted.</td></tr></tbody></table></figure>



<hr class="wp-block-separator has-alpha-channel-opacity"/>



<p class="wp-block-paragraph">In the food service industry, equipment breakdowns can be disruptive and costly. That&#8217;s why FWEParts is committed to providing step-by-step tutorials that make equipment repairs a breeze. If you&#8217;re facing issues with the ELAN Control Board used in many FWE units, our service video offers a comprehensive guide to easily troubleshoot it using common tools. We&#8217;re here to support you every step of the way, so don&#8217;t hesitate to reach out to us at 1-615-805-3270 or <a href="mailto:service@hatcodirect.com">service@hatcodirect.com</a> if you have any questions or concerns. For a full list of video tutorials for FWE parts, check out this <a href="https://www.youtube.com/playlist?list=PLPyd_Uwy5f73F9oCC3NbIivtGe0p8fH4d">youtube playlist</a>.</p>
<p>The post <a href="https://www.hatcodirect.com/how-to-troubleshoot-an-elan-t-stat-ele-control-board-for-fwe-equipment/">How to Troubleshoot an ELAN (T-STAT ELE) Control Board for FWE Equipment</a> appeared first on <a href="https://www.hatcodirect.com">OEM Parts for Hatco Equipment | Hatco Trade Direct Parts</a>.</p>
]]></content:encoded>
					
		
		
			</item>